TS4500 tape library Error code

Table 1. Library events
Error code Description Severity SNMP trap ID URC

0001 Cartridge {VOLSER} could not be read. Informational 201 NA

0002 Cartridge {VOLSER} could not be written to. Informational 202 NA

0003 Cartridge {VOLSER} had a read, write, or positioning error. Warning 203 NA

0004 Cartridge {VOLSER} had a read, write, or positioning error because of faulty media. Warning 204 NA

0005 Cartridge {VOLSER} could not be read from because of faulty media or a faulty drive. Warning 205 0xC005
0006 Cartridge {VOLSER} could not be written to or there was a positioning error because of faulty media or a faulty drive. Warning 206 NA

0007 Cartridge {VOLSER} reached its end of life. Warning 207 NA

0008 Cartridge {VOLSER} is not suitable for long term data storage. Warning 208 NA

0009 A write command failed because cartridge {VOLSER} is write-protected. Informational 209 NA

000A A drive unload was attempted while media removal was prevented. Informational 210 NA

000B A cleaning tape was loaded into a drive. Informational 211 NA

000C Cartridge {VOLSER} is not supported by the drive. Informational 212 NA

000D Cartridge {VOLSER} had a mechanical failure. The cartridge was unloaded. Warning 213 NA

000E Cartridge {VOLSER} had a mechanical failure. The cartridge was not unloaded. Error 214 0xC00E

000F A drive detected the cartridge memory in cartridge {VOLSER} failed. Warning 215 NA

0010 Cartridge {VOLSER} was manually removed from a drive with a read or write in process. Informational 216 NA

0011 A drive rejected a write attempt to a read-only cartridge {VOLSER}. Informational 217 NA

0012 At load time, a drive detected a corrupted directory for cartridge {VOLSER}. Warning 218 NA

0013 Cartridge {VOLSER} was nearing its end of life If you encounter this error, perform the following steps from the host:
Copy the data from the expiring cartridge to a different cartridge.
Eject the expiring cartridge and remove it from the library. Warning 219 N/A

0014 A drive requested a cleaning. Informational 220 NA

0015 A drive requested a routine cleaning. Informational 221 NA

0016 A drive detected an expired cleaning cartridge {VOLSER}. Informational 222 NA

0017 A drive detected an invalid cleaning cartridge {VOLSER}. Warning 223 NA

0018 A drive reported an undefined error. Informational 224 NA

0019 Drive Fibre channel interface failed. Error 225 0xC020

001A Drive cooling fan failed. Error 226 0xC01A

001B Drive power supply failed. Error 227 0xC01B

001C A drive reported an undefined error. Informational 228 NA

001D Drive preventive maintenance required. Informational 229 N/A

001E Drive failed. You must reset the drive to recover it. Error 230 0xC01E

001F Drive internal power-on self-tests failed. Error 231 0xC01F

0020 Drive Fibre channel interface failed. Error 232 0xC020

0021 A failure occurred that requires cartridge {VOLSER} to be demounted from the drive and retried. Warning 233 NA

0022 A drive firmware update process failed.. Informational 234 NA

0023 A drive detected that the humidity is outside the specified operational limits. Warning 235 NA

0024 A drive detected that the temperature is outside the specified operational limits. Warning 236 NA

0025 Drive power-supply voltages are outside the specified operational limits. Warning 237 0xC025

0026 A drive reported predictive failure of the hardware. Error 238 NA

0027 A drive reported a condition that requires drive diagnostics. Error 239 N/A

0028 A drive reported an undefined error. Informational 240 NA

0029 A drive reported an undefined error. Informational 241 NA

002A A drive reported an undefined error. Informational 242 NA

002B A drive reported an undefined error. Informational 243 NA

002C A drive reported an undefined error. Informational 244 NA

002D A drive reported an undefined error.Informational 245 NA

002E A drive reported an undefined error. Informational 246 NA

002F A drive reported an undefined error. Informational 247 NA

0030 A drive reported an undefined error. Informational 248 NA

0031 Cartridge {VOLSER} was initialized as partitioned or capacity-scaled. Informational 249 NA

0032 Cartridge {VOLSER} statistics lost. Informational 250 N/A

0033 At unload time, a drive detected a corrupted directory for cartridge {VOLSER}. Warning 251 N/A

0034 Cartridge {VOLSER} system area could not be written to. Warning 252 NA

0035 Cartridge {VOLSER} system area could not be read. Warning 253 NA

0036 Cartridge {VOLSER} does not have a valid start of data. Warning 254 NA

0037 Cartridge {VOLSER} could not be loaded and threaded. Warning 255 NA

0038 Cartridge {VOLSER} could not be unloaded. Error 256 0xC038

0039 Drive library interface failed. Warning 257 NA

003A A drive performed a self-reset. Informational 258 N/A

003B WORM cartridge {VOLSER} has suspect data. Warning 259 NA

003C An overwrite command failed for WORM cartridge {VOLSER}. Informational 260 NA

003D A drive is configured to require encryption, but encyption is not enabled. Warning 261 N/A

003E A drive reported an undefined error.Informational 262 NA

003F A drive reported an undefined error. Informational 263 NA

0040 A drive reported an undefined error. Informational 264 NA

0200 I/O station full. Informational 401 NA

0201 The I/O station has been open for five or more minutes. Warning 405 NA

0202 An I/O station was opened. Informational483 NA

0203 An I/O station was closed. Informational 484 NA

0210 The library ran out of LTO cleaning cartridges. Warning 403 NA

0211 The library ran out of 3592 cleaning cartridges. Warning 409 NA

0212 LTO cleaning cartridge {VOLSER} expired Warning 406 NA

0213 3592 cleaning cartridge {VOLSER} expired Warning 410 NA

0214 The library was almost out of licensed LTO storage slots Warning 424 NA

0215 The library was almost out of licensed 3592 storage slots Warning 425 NA

0216 The library ran out of licensed 3592 storage slots. Warning 426 NA

0217 The library ran out of licensed LTO storage slots Warning 427 NA

0218 The logical library {LOG_LIB} was almost full Warning 416 NA

0219 The logical library {LOG_LIB} was full. Warning 402 NA

021A A shuffle operation failed because there were no open slots in the library Warning 407 NA

021C The library detected a new unassigned cartridge {VOLSER}. Warning 421 NA

021E Cartridge {VOLSER} could not be assigned to logical library {LOG_LIB} because VIO was full. Warning 478 NA

0220 A library door was opened. Warning 16 NA

0221 All library doors were closed Informational 422 NA

0230 A frame inventory was started. Informational 429 NA

0240 Call home started Informational 431 NA

0241 Call home failed Warning 415 NA

0242 Test call home started Informational 432 NA

0243 Required LTO diagnostic cartridge was not found at the required location. Informational 433 NA

0244 Required 3592 diagnostic cartridge was not found at the required location. Informational 434 NA

0245 Call home finished Informational 432 NA

0247 Service logs exported to IBM Informational 482 N/A

0248 Library snapshot created. Informational 0 NA

0249 System console not responding Warning 495 N/A

0250 A cartridge that cannot be encrypted was loaded into a drive that is set to encrypt all cartridges Warning 420 NA

0261 During a test, the encryption key manager address failed. Warning 419 NA

0262 During a test, the encryption key manager path failed Warning 419 NA

0263 During a test, the encryption key manager full path check failed Warning 419 NA

0264 The security settings HTTPS certificate will expire in 30 days. Warning 462 NA

0265 The security settings HTTPS certificate has expired. Error 460 xA763

0280 Accessor {ACCESSOR} could not read a barcode. Warning 32 0xA4C5

0290 There is no Media Verification drive for cartridge {VOLSER} generation. Warning 464 NA

0291 Media Verification failed for cartridge {VOLSER} Error 465 0xA790

0292 There is only one Media Verification drive assigned to the logical library {LOG_LIB} and it failed Error 466 0xA791

0293 Media Verification passed for cartridge {VOLSER} Informational 0 NA

0295 Media Verification drive failed after multiple put errors. Error 467 0xA792

02B1 A move failed because there was not a demount destination available. Warning 407 N/A

02B2 A move failed because there was not a Tier0 destage destination available Warning 407 N/A

02B3 A move failed because there was not an elastic destage destination available. Warning 407 N/A

02B4 A move failed because there was not an import destination available. Warning 407 N/A

02B5 A move failed because there was not an ERP destination available. Warning 407 N/A

02C0 Cartridge {VOLSER} with an L7 density was unloaded. Informational 0 NA

02C1 Cartridge {VOLSER} with an M8 density was unloaded. Informational 0 NA

02D0 Accessor {ACCESSOR} could not read cartridge {VOLSER} barcode label Informational 491 NA

02D1 Cartridge CM Volser changed from {VOLSER} to {VOLSER} Informational 492 NA

0300 An LCC was unable to communicate with an air conditioning unit. Error 472 N/A

0302 An LCC was unable to communicate with a temperature and humidity sensor Error 474 N/A

0303 An air conditioning compressor was off unexpectedly Error 475 N/A

0304 An environmental LED state was changed to Red - Do Not Open Door Informational 0 N/A

0305 An environmental LED state was changed to Yellow - Use Caution when Opening Door Informational 0 N/A

0306 An environmental LED state was changed to Green - OK to Open Door Informational 0 N/A

0307 Drives were set to environmental protection mode Warning 476 N/A

0308 Ambient environment was out of specification at {TEMPERATURE}°C and {HUMIDITY}% RH. Warning 477 N/A

0310 A request to open a door was made Informational 0 N/A

0311 Library service was completed Informational 0 N/A

0312 Library service exceeded 30 minutes Error 479 N/A

0313 Library air conditioning normal operation was resumed Informational 0 N/A

0320 Ship preparation started Informational 501 N/A

0321 Ship preparation finished successfully Informational 502 N/A

0322 Ship preparation failed Error 503 N/A

0700 The state of the library changed from {OLD_STATE} to {NEW_STATE}. Informational 0 N/A

0701 The state of drive {DRIVE} changed from {OLD_STATE} to {NEW_STATE}. Informational 0 N/A

0702 The state of accessor {ACCESSOR} changed from {OLD_STATE} to {NEW_STATE}. Informational 0 N/A

0703 The state of LCC node card {FRAME} changed from {OLD_STATE} to {NEW_STATE}. Informational 0 N/A

0704 The state of ACC node card {ACCESSOR} changed from {OLD_STATE} to {NEW_STATE}. Informational 0 N/A

0705 The state of MDA node card {ACCESSOR} changed from {OLD_STATE} to {NEW_STATE}. Informational 0 N/A

0706 The state of Frame {FRAME} changed from {OLD_STATE} to {NEW_STATE}. Informational 0 N/A

0800 A user logged in to the GUI from {IPADDRESS} Informational 440 NA

0801 A user failed to login from {IPADDRESS} Informational 441 NA

0802 A library setting was changed Informational 443 NA

0803 A logical library {LOG_LIB} setting was changed Informational 444 NA

0804 A tape drive setting was changed Informational 445 NA

0805 A cartridge setting was changed Informational 446 NA

0806 Library firmware update started. Informational 447 NA

0807 Library firmware update failed Informational 455 NA

0808 A corrupted library firmware image was downloaded. Informational 456 NA

0809 Drive firmware update failed Informational 457 NA

080A Library firmware update finished. Informational 458 NA

080B Library firmware update finished. Informational 458 NA

080C Accessor {ACCESSOR} FRU replacement finished. Informational 448 NA

080D Drive FRU replacement finished Informational 449 NA

080E A drive serial number changed Informational 450 NA

080F A drive was reset Informational 451 NA

0810 An administrator password was changed Informational 453 NA

0811 An SNMP test trap was sent from the GUI Informational 408 NA

0812 A user logged out of the GUI from {IPADDRESS} Informational 442 NA

0813 Library security settings changed. Informational 20 NA

0814 The library was set offline Informational 21 NA

0815 A drive was offline Informational 22 NA

0816 Accessor {ACCESSOR} MDA card was reset by a user. Informational 452 NA

0817 Accessor {ACCESSOR} ACC card was reset by a user. Informational 452 NA

0818 An LCC card was reset by user. Informational 452 NA

0819 All node cards were reset by user. Informational 452 NA

081A The access recovery button was pressed. Informational 460 NA

081B User account locked Informational 461 NA

081C A service user logged in to the GUI from {IPADDRESS} Informational 471 NA

081D Accessor {ACCESSOR} MDA card was reset. Informational 485 NA

081E Accessor {ACCESSOR} ACC card was reset. Informational 485 NA

0820 A drive beacon was turned on Informational 487 NA

0821 A drive beacon was turned off Informational 488 NA

0822 A drive was hard reset Informational 489 NA

0900 Calibrate frame started. Informational 0 NA

0901 Calibrate frame finished. Informational 0 NA

0902 Accessor {ACCESSOR} calibrate started. Informational 0 NA

0903 Accessor {ACCESSOR} calibrate finished. Informational 0 NA

0904 Calibrate I/O started. Informational 0 NA

0905 Calibrate I/O finished. Informational 0 NA

0906 Calibrate drive started. Informational 0 NA

0907 Calibrate drive finished. Informational 0 NA

090C Drive firmware update started. Informational 447 NA

090D Drive firmware update finished. Informational 459 NA

090E Library firmware update started. Informational 447 NA

090F Library firmware update finished. Informational 458 NA

0911 Inventory finished. Informational 430 NA

0912 Inventory with audit started. Informational 429 NA

0913 Inventory with audit finished. Informational 430 NA

0914 Library verify started. Informational 0 NA

0915 Library verify finished. Informational 0 NA

0916 Library diagnostics started. Informational 0 NA

0917 Library diagnostics finished. Informational 0 NA

091A Drive FRU replacement started. Informational 0 NA

091C Drive log download started. Informational 0 NA

091D Drive log download finished. Informational 0 NA

091E Discover hardware started. Informational 0 NA

091F Discover hardware finished. Informational 0 NA

0920 VOLSER range update started. Informational 0 NA

0921 VOLSER range update finished. Informational 444 NA

0922 Accessor {ACCESSOR} FRU replacement started. Informationa 448 NA

0924 Calibrate library started. Informational 0 NA

0925 Calibrate library finished. Informational 0 NA

0926 Drive FRU replacement started Informational 449 NA

0927 Drive FRU replacement finished Informational 449 NA

0928 Drive test started. Informational 0 NA

0929 Drive test finished. Informational 0 NA

092A The library was reset. Informationa 0 NA

2000 The pause button failed. Error 2 NA

2001 The access recovery button failed. Error 2 NA

2002 Library pause button was pressed Informational 480 NA

2124 More than 8 LCC detected on library string Warning 468 NA

2125 LCC card failed over Warning 469 NA

2127 An LCC communication with Accessor {ACCESSOR} MDA card timed out. Warning 499 N/A

2128 An LCC communication with Accessor {ACCESSOR} ACC card timed out. Warning 500 N/A

2380 Accessor {ACCESSOR} ACC card failed. Error 2 0xA413

2381 Accessor {ACCESSOR} ACC card CAN bus 1 failed. Error 2 0xA413

2382 Accessor {ACCESSOR} ACC card CAN bus 2 failed. Error 2 0xA413

2481 Accessor {ACCESSOR} MDA card CAN bus 1 failed. Error 2 0xA414

2482 Accessor {ACCESSOR} MDA card CAN bus 2 failed. Error 2 0xA414

2484 An LCC card was not responding over Ethernet Warning 2 0xA427

2500 FPGA L Frame location was incorrect Warning 481 N/A

3021 A library side door was opened. Warning 16 NA

3024 A library side door was not detected Error 2 0xA43B

3025 The service bay barrier was down when a side door was opened Error 2 0xA43C

3026 The service bay barrier was up when a side door was closed Error 2 0xA43C

3081 A frame was not found Error 2 0xA431

3430 A 12V DC power supply would not turn on Error 28 0xA514

34A1 A 12V DC power supply was not detected Error 28 0xA457

3746 A drive was miscabled Error 2 0xA624

3749 A BPC-G231-to-BPC cable was not connected correctly. Error 2 0xA627

3750 An ASC to flex track cable was not plugged correctly Error 2 0xA628

3752 An LCC to DSC communication failed Warning 486 NA

3753 A frame-to-frame cable was not connected correctly. Error 505 NA

3822 An LCC to drive communication failed Warning 1 0xB80A

3833 An LCC card could not get a response from a drive Error 1 0xB701

3834 Communication between an LCC card and a drive failed on Ethernet Error 1 0xB702

3835 An LCC card could not communicate with a drive Error 1 0xB703

3839 A drive or canister type did not match the configuration Error 1 0xB707

383B A drive diagnostic test returned an invalid status Error 1 0xB709

383C More than 128 Drives detected on library string Warning 470 NA

4081 Gripper {GRIPPER} did not move. Error 2 0xB401

4082 Gripper {GRIPPER} encountered an unexpected hard stop while extending. Error 2 0xB402

4083 Gripper {GRIPPER} encountered an unexpected hard stop while retracting. Error 2 0xB403

4084 Gripper {GRIPPER} encountered a high current condition while extending. Error 2 0xB404

4085 Gripper {GRIPPER} encountered a high current condition while retracting. Error 2 0xB405

4086 Gripper {GRIPPER} was unable to find a hard stop while extending Error 2 0xB406

4087 Gripper {GRIPPER} was unable to find a hard stop while retracting Error 2 0xB407

4088 Gripper {GRIPPER} was unable to get cartridge {VOLSER} Error 2 0xB408

4089 Gripper {GRIPPER} was unable to put cartridge {VOLSER} Error 2 0xB409

408A Gripper {GRIPPER} lost power. Error 2 0xB40A

408B Gripper {GRIPPER} encountered a low current condition while retracting. Error 2 0xB40B

408C Gripper {GRIPPER} lost a cartridge. Error 2 0xB40C

408D Gripper {GRIPPER} is not aligned properly in the gripper cage. Error 2 0xB40D

4181 Gripper {GRIPPER} sensor was blocked when it should not have been. Error 2 0xB40E

4182 Gripper {GRIPPER} sensor was not blocked when it should have been. Error 2 0xB40F

4183 Gripper {GRIPPER} sensor was in a degraded state. Error 7 0xB40E

4184 Gripper {GRIPPER} sensor failed. Error 2 0xB40E

4221 Accessor {ACCESSOR} X home sensor was blocked when it should not have been. Error 2 0xA47A

4380 Accessor {ACCESSOR} X home sensor was not found during a re-zero. Error 2 0xA471

4480 Accessor {ACCESSOR} Y home sensor was blocked when it should not have been. Error 2 0xA480

4481 Accessor {ACCESSOR} Y home sensor was not found during rezero. Error 2 0xA481

4580 Accessor {ACCESSOR} X motor did not move. Error 2 0xA490

4581 Accessor {ACCESSOR} X motion could not find a hard stop while moving left. Error 2 0xA491

4582 Accessor {ACCESSOR} X motion could not find a hard stop while moving right. Error 2 0xA492

4583 Accessor {ACCESSOR} X motion encountered an unexpected hard stop while moving left. Error 2 0xA493

4584 Accessor {ACCESSOR} X motion encountered an unexpected hard stop while moving right. Error 2 0xA494

4585 Accessor {ACCESSOR} X motion required excessive force to move left. Error 2 0xA495

4586 Accessor {ACCESSOR} X motion required excessive force to move right. Error 2 0xA496

4587 Accessor {ACCESSOR} X motion failed due to loss of 40 V dc. Error 2 0xA40A

4588 Accessor {ACCESSOR} X motion motor driver failed. Error 2 0xA498

4589 Accessor {ACCESSOR} X motion position drift occurred. Error 2 0xA499

4590 Accessor {ACCESSOR} X motion accessor rezero completed. Informational 2 0xA475

4591 Accessor {ACCESSOR} rezero completed. Informational 2 0xA476

4680 Accessor {ACCESSOR} Y motor did not move. Error 2 0xA4A0

4681 Accessor {ACCESSOR} Y motion could not find a hard stop while moving up. Error 2 0xA4A1

4682 Accessor {ACCESSOR} Y motion could not find a hard stop while moving down. Error 2 0xA4A2

4683 Accessor {ACCESSOR} Y motion encountered an unexpected hard stop while moving up. Error 2 0xA4A3

4684 Accessor {ACCESSOR} Y motion encountered an unexpected hard stop while moving down. Error 2 0xA4A4

4685 Accessor {ACCESSOR} Y motion required excessive force to move up. Error 2 0xA4A5

4686 Accessor {ACCESSOR} Y motion required excessive force required to move down. Error 2 0xA4A6

4687 Accessor {ACCESSOR} Y motion failed because of a loss of 40V DC power. Error 2 0xA40B

4688 Accessor {ACCESSOR} Y motion failed. Error 2 0xA4A8

4689 Accessor {ACCESSOR} Y motion failed because of drift. Error 2 0xA4A9

4690 Accessor {ACCESSOR} Y motion accessor rezero completed Informational 2 0xA485

4691 Accessor {ACCESSOR} Y motion drift was suspected. Informational 2 0xA486

4780 Accessor {ACCESSOR} pivot motor could not move. Error 2 0xA5B0

4781 Accessor {ACCESSOR} pivot motion could not find a hard stop. Error 2 0xA5B1

4782 Accessor {ACCESSOR} pivot motion could not find a hard stop. Error 2 0xA5B2

4783 Accessor {ACCESSOR} pivot motion encountered an unexpected hard stop. Error 2 0xA5B3

4784 Accessor {ACCESSOR} pivot motion encountered an unexpected hard stop. Error 2 0xA5B4

4785 Accessor {ACCESSOR} pivot motion required excessive force to pivot. Error 2 0xA5B5

4786 Accessor {ACCESSOR} pivot motion required excessive force to pivot. Error 2 0xA5B6

4787 Accessor {ACCESSOR} pivot motion failed because of a power loss. Error 2 0xA4B8

4840 Accessor {ACCESSOR} XY positioning could not be determined. Error 2 0xA4B9

4880 Accessor {ACCESSOR} failover occurred. Error 2 0xA4BA

4890 Accessor {ACCESSOR} XY impact was detected Error 2 0xA4BB

4891 Accessor {ACCESSOR} detected a cartridge in the accessor or gripper's path. Error 2 0xA4BB

48A0 Accessor {ACCESSOR} detected an obstacle in the accessor or gripper's path Error 2 0xA4BB

48B0 Accessor {ACCESSOR} re-zero failed. Error 2 0xA4BC

4900 The number of cartridges in the library needs to be 4 times the number of frames for multi-frame verification testing Error 0 N/A

4901 Multi-frame verification test failed Error 0 N/A

4902 Multi-frame verification test completed successfully Informational 0 N/A

4903 Multi-frame verification test has started Informational 0 N/A

5B22 Accessor {ACCESSOR} barcode scanner cannot be triggered. Error 2 0xA4C3

5B23 Accessor {ACCESSOR} barcode scanner cannot be triggered. Error 2 0xA4C4

5B24 Accessor {ACCESSOR} barcode scanner with invalid VPD was detected. Error 2 0xA4C5

5B82 Accessor {ACCESSOR} barcode scanner loopback test failed. Error 2 0xA4C2

5B86 Accessor {ACCESSOR} could not read a frame barcode label. Error 2 0xA4CE

5B89 Accessor {ACCESSOR} could not read an I/O station barcode label. Error 2 0xA4C9

5B8A Accessor {ACCESSOR} barcode scanner communication failed Informational 490 NA

9080 Accessor {ACCESSOR} found an empty source element. Error 24 0xA4D0

9180 An inventory with audit failed Error 2 0xA4D5

9181An inventory failed Error 2 0xA4D5

9250 Accessor {ACCESSOR} had only one usable gripper for operation. Error 2 0xA4D2

9251 Accessor {ACCESSOR} had no usable grippers for operation. Error 2 0xA4D2

9480 Accessor {ACCESSOR} found a destination element unexpectedly full. Error 24 0xA4D1

A010 Cartridge {VOLSER} was not detected from the previous inventory. Error 24 0xA950

A012 An inventory self-correction started. Informational 24 0xA952

A080 Accessor {ACCESSOR} had no grippers installed. Error 2 0xB420

A08C A drive type that was incompatible with the original drive type was detected. Error 2 0xB32C

B061 Could not lock I/O station door Error 17 0xB091

B062 Could not unlock I/O station door Error 17 0xB092

B063 Could not open I/O station door Error 17 0xB093

B064 Could not close I/O station door Error 17 0xB094

B066 A magazine type incompatible with the library was detected in an I/O Statio Warning 17 N/A

B220 Gripper {GRIPPER} could not get cartridge {VOLSER} from I/O station. Error 17 0xB320

B221 Gripper {GRIPPER} could not put cartridge {VOLSER} in I/O station. Error 17 0xB321

B382 Gripper {GRIPPER} could not get cartridge {VOLSER} from slot. Error 2 0xB150

B383 Gripper {GRIPPER} could not get cartridge {VOLSER} out of slot. Error 2 0xB152

B384 Gripper {GRIPPER} found cartridge {VOLSER} stuck in the slot Error 2 0xB153

B388 Gripper {GRIPPER} could not put cartridge {VOLSER} in slot. Error 2 0xB151

B480 Accessor {ACCESSOR} X or Y motion command exceeded the limits of the library Error 4 0xAACA

B481 Accessor {ACCESSOR} asymmetrical motor limits were detected Error 4 0xAACB

B500 Accessor {ACCESSOR} calibration failed. Error 2 0xB190

B580 Accessor {ACCESSOR} could not find a column fiducial. Error 2 0xB361

B581 Accessor {ACCESSOR} encountered a column tilt outside the specified operational limits Error 493 N/A

B582 Accessor {ACCESSOR} found a column fiducial calibration value is outside the operational limits against stored value Warning 496 N/A

B583 Accessor {ACCESSOR} found a column calibration value out of range from adjacent column Warning 498 N/A

B584 Accessor {ACCESSOR} encountered a column tilt close to the operational limits. Warning 506 N/A

B681 Accessor {ACCESSOR} could not find a drive fiducial. Error 2 0xC020

B682 Accessor {ACCESSOR} found a drive fiducial calibration value is outside the operational limits against stored value Warning 497 N/A

B790 Accessor {ACCESSOR} could not find an I/O station fiducial. Error 2 0xB370

B791 Accessor {ACCESSOR} could not find an I/O station fiducial. Error 2 0xB170

B792 Accessor {ACCESSOR} detected an un-calibrated frame. Error 2 0xB171

B793 Accessor {ACCESSOR} encountered an I/O station tilt outside the specified operational limits Error 494 N/A

B891 A drive did not release the cartridge. This failure could be caused by a cartridge gate not opening due to a gate mechanical problem. Error 2 0xC031

B893 A drive did not load the cartridge Error 2 0xC033

CCCA A memory allocation or stack error occurred. Informational 4 0xACCC

CCCC A library firmware error occurred. Informational 4 0xACCC

CCCF X authorization failed. Error 4 0xACCF

You can power TS4500 tape library in three basic ways (1) Standard Configuration, (2) Using Power Distribution Unit
TS4500 tape library (PDU) Feature Code 1951/1952, (3) Using Feature code 1751/1752 with a Top Rack.
中国·北京 联系方式:
1)联系人:   霍经理
2)手 机: 13301272832 (微信同号)
3)QQ: 619804118
4)联系电话:(010)82666745
5)传   真:(010)82666745
6)E-mail:   bjslkc@163.com
7)公司:北京深蓝融鑫科技发展有限公司
8)地址:北京市海淀区西北旺
9)公司地址、乘车路线及公司位置地图
 

Beijing ShenLan Rongxin Technology Development Co., Ltd. All Rights Reserved.
北京深蓝融鑫科技发展有限公司 版权所有,不得转载.
京ICP备05042544号