一、HDS VSP G400 and VSP G600 storage system components -->疑难问题解决方案 |
|
|
Model lists
HDS VSP G400 and VSP G600 controller model lists -->疑难问题解决方案
|
|
|
CBLM controller optional components -->疑难问题解决方案
|
|
|
CBLM controller optional components -->疑难问题解决方案
|
|
|
Drive tray model lists
SFF drive tray components (AC power) -->疑难问题解决方案
|
|
|
SFF drive tray optional components -->疑难问题解决方案
|
Model number |
Part name |
Quantity |
|
DKC-F810I-200MEM1 |
200 GB, MLC, 12-Gbps, SFF,flash drive |
0-24 |
|
DKC-F810I-300KCMC1 |
300 GB, 15kmin, 6-Gbps, SAS,SFF, drive |
0-24 |
|
DKC-F810I-400MEM1 |
400GB, MLC, 12-Gbps, SFF,flash drive |
0-24 |
|
DKC-F810I-600JCM1 |
600 GB, 10kmin, 6-Gbps, SAS,SFF, drive (contains BNST) |
0-24 |
|
DKC-F810I-600JCMC1 |
600 GB, 10kmin, 6-Gbps, SAS,SFF, drive |
0-24 |
|
DKC-F810I-600KGM1 |
600 GB, 15kmin, 6-Gbps, SAS,SFF, drive |
0-24 |
|
|
|
SFF drive tray optional components -->疑难问题解决方案
|
Model number |
Part name |
Quantity |
|
DKC-F810I-1R2JCMC1 |
1.2-TB, 10kmin, 6-Gbps, SAS,SFF, drive |
0-24 |
|
DKC-F810I-1R8JGM1 |
1.8-TB, 10kmin, 6-Gbps, SAS,SFF, drive |
0-24 |
|
DKC-F810I-1R9MEM1 |
1.92 TB, 2.5-inch, MLC, 12-Gbps, SAS, drive |
0-24 |
|
|
1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. |
|
LFF drive tray components -->疑难问题解决方案
|
|
|
Optional LFF drive tray components -->疑难问题解决方案
|
Model number |
Part name |
Quantity |
|
DKC-F810I-400M6M1 |
400 GB, LFF, Flash drive |
0-12 |
|
DKC-F810I-1R2J5MC1 |
1.2 TB, SAS, LFF, drive |
0-12 |
|
DKC-F810I-1R8J6M1 |
1.8 TB, 10k, 6-Gbps, SAS, LFF,drive |
0-12 |
|
DKC-F810I-4R0H3M1 |
4 TB, 7.2K, 6-Gbps, SAS, LFF,drive (contains BNST) |
0-12 |
|
DKC-F810I-4R0H3MC1 |
4 TB, 7.2K, 6-Gbps, SAS, LFF,drive |
0-12 |
|
DKC-F810I-6R0H9M1 |
6 TB, 7.2K, 12-Gbps, SAS, LFF,drive |
0-12 |
|
DKC-F810I-10RH9M |
10 TB, 7.2K, 12-Gbps, SAS,LFF, drive |
0-12 |
|
|
|
FMD tray components -->疑难问题解决方案
|
|
|
FMD tray optional components -->疑难问题解决方案
|
Model number |
Part name |
Quantity |
|
DKC-F710I-1R6FM1 |
1.75 TB, MLC, 6-Gbps, Flash Module Drive |
0-12 |
|
DKC-F710I-3R2FM1 |
3.5, TB, MLC, 6-Gbps, Flash Module Drive |
0-12 |
|
DKC-F810I-1R6FN1 |
1.75 TB, Flash Module Drive |
0-12 |
|
DKC-F810I-3R2FN1 |
3.5 TB, Flash Module Drive |
0-12 |
|
DKC-F810I-6R4FN1 |
7 TB, Flash Module Drive |
0-12 |
|
DKC-F810I-7R0FP1 |
7 TB, MLC, 12-Gbps, Flash Module Drive |
0-12 |
|
DKC-F810I-14RFP1 |
14 TB, MLC, 12-Gbps, Flash Module Drive |
0-12 |
|
|
|
Dense intermix drive tray components -->疑难问题解决方案
|
|
|
Dense intermix drive tray optional components (VSP Gx00 models only) -->疑难问题解决方案
|
Model number |
Part name |
Quantity |
|
DKC-F810I-400M8M1 |
400 GB, MLC, 12-Gbps, flash drive |
0-60 |
|
DKC-F810I-1R2J7M1 |
1.2 TB, 10k, 6-Gbps, SAS, SFF,drive (contains BNST) |
0-60 |
|
DKC-F810I-1R2J7MC1 |
1.2 TB, 10k, 6-Gbps, SAS, SFF,drive |
0-60 |
|
DKC-F810I-1R8J8M1 |
1.8 TB, 10k, 6-Gbps, SAS, LFF drive |
0-60 |
|
DKC-F810I-1R9MEM1 |
1.92 TB, 2.5-inch, MLC, 12-Gbps, SAS, drive |
0-60 |
|
DKC-F810I-4R0H4M1 |
4 TB, 7.2K, 6-Gbps, SAS, LFF,drive (contains BNST) |
0-60 |
|
DKC-F810I-4R0H4MC1 |
4 TB, 7.2K, 6-Gbps, SAS, LFF,drive |
0-60 |
|
DKC-F810I-6R0HLM1 |
6 TB, 7.2K, 12-Gbps, SAS, LFF,drive |
0-60 |
|
DKC-F810I-10RHLM1 |
10 TB, 7.2K, 12-Gbps, SAS,LFF, drive |
0-60 |
|
|
Battery specifications
The following table shows the lifetime expectancy of the batteries installed in
the storage system. -->疑难问题解决方案
|
Storage system intake temperature CBLM -->疑难问题解决方案
|
|
VSP G200, G400, G600, G800 -->疑难问题解决方案
• VSP G1000, G1500 -->疑难问题解决方案
• VSP F1500 -->疑难问题解决方案
• Unified Storage VM -->疑难问题解决方案
• Virtual Storage Platform -->疑难问题解决方案
• Universal Storage Platform V -->疑难问题解决方案
• Universal Storage Platform VM -->疑难问题解决方案
• SANRISE Universal Storage Platform-->疑难问题解决方案
• SANRISE Network Storage Controller-->疑难问题解决方案
• Unified Storage -->疑难问题解决方案
• Adaptable Modular Storage -->疑难问题解决方案
• Workgroup Modular Storage -->疑难问题解决方案
• SANRISE9900V series -->疑难问题解决方案
• SANRISE9500V series -->疑难问题解决方案
• TagmaStore Universal Storage Platform-->疑难问题解决方案
• TagmaStore Network Storage Controller-->疑难问题解决方案
• Lightning 9900V series -->疑难问题解决方案
• Thunder 9500V series -->疑难问题解决方案
• Virtual Storage Platform VX7 -->疑难问题解决方案
• VP9500 -->疑难问题解决方案
• H24000 -->疑难问题解决方案
• H20000 -->疑难问题解决方案
• SANRISE H12000 -->疑难问题解决方案
• SANRISE H10000 -->疑难问题解决方案
• SANRISE H1024/H128-->疑难问题解决方案
• XP7 Storage -->疑难问题解决方案
• P9500 -->疑难问题解决方案
• XP24000 -->疑难问题解决方案
• XP20000 -->疑难问题解决方案
• XP12000 -->疑难问题解决方案
• XP10000 -->疑难问题解决方案
• XP1024/XP128 -->疑难问题解决方案
|
|
中国·北京 重庆 联系方式:
|
|
|
|