深蓝快车
专业技术服务提供商;专业存储设备提供商

EMC VNX5400 断电后,两个服务处理器都处于服务模式

产品

技术

配件

IT疑难问题解决方案1

IT疑难问题解决方案2

小型机服务

服务器服务

存储服务

维保

机房搬迁

操作系统|双机

数据库

备份/恢复

Oracle灾备

应急服务

楼宇监控

深蓝快车

技术中心

案例

联系我们

SPA 红灯
SPB 红灯
控制器 A 红灯
控制器 B 红灯
存储控制 A (主要) 红灯
存储控制 B 红灯
Storage Processor A (Primary) red light
Storage Processor B red light
存储控制 A (主要) 模式: 服务
存储控制 B 模式: 服务
Storage Processor A (Primary) Mode: Service
Storage Processor B Mode: Service
SPA Empty
SPB Empty
SPA Empty Current State: Not Present
SPB Empty Current State: Not Present
SPA Base Module A Faulted
SPB Base Module B Faulted
SPA CPU Module A Faulted
SPB CPU Module B Faulted
SPA DIMMS A Faulted
SPB DIMMS B Faulted
SPA I/O Modules Empty
SPB I/O Modules Empty
SPA I/O Modules Solt A0 Faulted
SPA I/O Modules Solt A1 Faulted
SPA I/O Modules Solt A2 Faulted
SPA I/O Modules Solt A3 Faulted
SPA I/O Modules Solt A4 Faulted
SPB I/O Modules Solt B0 Faulted
SPB I/O Modules Solt B1 Faulted
SPB I/O Modules Solt B2 Faulted
SPB I/O Modules Solt B3 Faulted
SPB I/O Modules Solt B4 Faulted
SPA Peer Boot State Invalid
SPB Peer Boot State Invalid
SPA Storage System Failure - Contact your Service Representative
SPB Storage System Failure - Contact your Service Representative
Bus 0 Enclosure 0 Disk8 Removed
Bus 0 Enclosure 0 Disk9 Removed
Bus 0 Enclosure 0 Disk10 Removed
Bus 0 Enclosure 0 Disk11 Removed
DPE(Bus 0 Enclosure 0) is faulted
SPS(Bus 0 Enclosure 0 BBU A) is faulted
Bus0 Enclosure 0 Power A Faulted
Bus0 Enclosure 0 Power B Faulted
BMC Indicated I/O Module Powr Disabled Error
EMC Control Station 无法启动
EMC Control Station 无法开机
IE 浏览器 无法访问EMC VNX5600 Unisphere 界面--》报java jre加载问题
Firefox 浏览器 无法访问EMC VNX5600 Unisphere 界面--》报java jre加载问题
Chrome 浏览器 无法访问EMC VNX5600 Unisphere 界面--》报java jre加载问题
IE JRE is required for this application to run.Please refer to the EMC,32-bit
Firefox JRE is required for this application to run.Please refer to the EMC,32-bit
Chrome JRE is required for this application to run.Please refer to the EMC,32-bit
IE JRE is required for this application to run.Please refer to the EMC,64-bit
Firefox JRE is required for this application to run.Please refer to the EMC,64-bit
Chrome JRE is required for this application to run.Please refer to the EMC,64-bit
Chrome JRE is required for this application to run.Please refer to the EMC,64-bit
Error: Unable to establish IPMI v2 / RMCP+ session,ipmitool.exe
how to replace a BBU in a VNX5600 System
how to replace a DPE in a VNX5600 System
how to replace a Disk in a VNX5600 System
how to replace a I/O Module in a VNX5600 System
how to replace a Power in a VNX5600 System
how to replace a Storage Processor (SP) in a VNX5600 System
how to replace a Storage Processor (SP) A in a VNX5600 System
how to replace a Storage Processor (SP) B in a VNX5600 System
怎样更换 BBU in a VNX5600 System
怎样更换 DPE in a VNX5600 System
怎样更换 磁盘 in a VNX5600 System
怎样更换 I/O Module in a VNX5600 System
怎样更换 电源 in a VNX5600 System
怎样更换 Storage Processor (SP) in a VNX5600 System
怎样更换 Storage Processor (SP) A in a VNX5600 System
怎样更换 Storage Processor (SP) B in a VNX5600 System
EMC 技术支持电话: 13301272832 (微信同号)
Moble: 13301272832 (微信同号)
Tel:  010-82666745
联系人:   霍经理
QQ:   619804118
E-mail:   bjslkc@163.com
公司:北京深蓝融鑫科技发展有限公司

EMC VNX5400 控制器失败(EMC VNX5400 Controller failure)-->解决方法

EMC VNX5400 -->解决方法

EMC VNX5400 Service Mode 服务模式(EMC VNX5400 BOOT Mode: Rescue Mode)-->解决方法

spb login: Password: *** WRING *** This Storage Porcess is Service Mode *** WRING *** *** Run "svc_diag" to view system info or "help" for service commands *** service@spb spb:>svc_diag -->解决方法 ============= Now executing basic state =========== *System Serial Number is: *System Friendly Host Name is:(one) *Current Software version: upc_KittyHawkPlus_28_2_upcBuilder-3.1.5.8711967-GXOSIS-RETAIL *Unisphere IP ADDRESS(ES):Unable to determine IP address(es) -->解决方法 *SSH ENbled: true *BOOT Mode: Rescue Mode -->解决方法 *Post Faults: 0x0000 *Backend Faults: 0x0000 *Rescue Reason: 0x1b20 -->解决方法 *Rescue reason for code 0x1b20 - There is problem with the system software on this Storage Collection and the contact you service provider. *** WARNING *** This Storage Processor is in Service Mode *** WARNING **** -->解决方法 *** Run "svc_diag" to view system info or "help" for service command *** -->解决方法

EMC VNX5400 存储的SPB DEGRADED状态 -->解决方法

EMC VNX5400: Both SPA & SPB Stuck in Service Mode -->解决方法 After power outage, both service processors are stuck in service mode. -->解决方法 Reseats and reboots have not been able to bring them out of service mode. -->解决方法 cannot ping the device anymore or use the gui, only direct serial connection works. -->解决方法 Techs had us Change SSD and SPA. -->解决方法 Tech then had us put OLD SSD back in NEW SPA. -->解决方法 Tech then had us change DPA:0.0 -->解决方法

svc_diag: ======== Now executing basic state ======== * System Friendly Host Name is: (none) * System Serial Number is: ----------------- * Current Software Version: NeoMain-2.4.4.22283-MAGNUM-RETAIL * Unisphere IP address (es): Unable to determine IP address -->解决方法 * SSH Status: SSH is disabled on this system. * Boot Mode: Rescue_Mode * Post Faults: No faults detected. (code 0x0000) * Backend Faults: No faults detected. (code 0x0000) * Boot Control Faults: (code 0x1102) -->解决方法 There is a problem with the system software on this Storage Processor (ADMIN). To attempt to correct this problem: Run Data Collection, check all cables, reboot each SP, and lastly try Reimaging each Storage Processor (SP). If the Service Code is shown below and is set to 0xFC12CDD1, some part of the system is Cache Dirty so contact support for resolution. * Rescue Reason: (code 0x1102) -->解决方法 There is a problem with the system software on this Storage Processor (ADMIN). To attempt to correct this problem: Run Data Collection, check all cables, reboot each SP, and lastly try Reimaging each Storage Processor (SP). If the Service Code is shown below and is set to 0xFC12CDD1, some part of the system is Cache Dirty so contact support for resolution. * Hint Code: Dart root LUNs are cache dirty, escalate to fix cache dirty (code 0xFC12CDD1) * SP Service Hint Code: 0xFC12CDD1 -->解决方法 Technicians have SSH into each SP and run the following: svc_cdca --list-cdca (list all cache dirty luns for current SP, clear any cache dirty luns for current SP, prepare any system luns for auto fsck.) Still no results as the SP's continue to reboot randomly.

EMC VNX5400:SPA和SPB都处于服务模式-->解决方法 EMC VNX5400:断电后,两个服务处理器都处于服务模式。-->解决方法 EMC VNX5400:重置和重新启动无法使其退出服务模式。-->解决方法 EMC VNX5400:无法再ping设备或使用gui,只能使用直接串行连接。-->解决方法

SP_B DEGRADED状态 -->解决方法 SP_A DEGRADED状态 -->解决方法 SPB DEGRADED状态 -->解决方法 SPA DEGRADED状态 -->解决方法

EMC VNX5400 SPB亮黄灯 -->解决方法

DELL EMC VNX54000 SP_B 亮黄灯 -->解决方法 DELL EMC VNX54000 SP_A 亮黄灯 -->解决方法 DELL EMC VNX54000 SPB 亮黄灯 -->解决方法 DELL EMC VNX54000 SPA 亮黄灯 -->解决方法

DELL EMC VNX5400 电源亮黄灯 -->解决方法

DELL EMC VNX54000 电源亮黄灯 -->解决方法 DELL EMC VNX54000 电源 亮黄灯 -->解决方法 DELL EMC VNX54000 风扇 亮黄灯 -->解决方法 DELL EMC VNX54000 电池 亮黄灯 -->解决方法 DELL EMC VNX54000 磁盘 亮黄灯 -->解决方法 Disk-array enclosure (DAE)亮黄灯 -->解决方法 disk processor enclosure (DPE) 亮黄灯 -->解决方法 SP Status/Fault 亮黄灯 -->解决方法 DPE enclosure fault 亮黄灯 -->解决方法 SP A/B Power fault 亮黄灯 -->解决方法 DPE enclosure power fault 亮黄灯 -->解决方法 System disk drives in DPE fault亮黄灯 -->解决方法 SP Status/Fault LEDs 亮黄灯 -->解决方法





DELL EMC VNX5400 控制器(Director) 失败(DELL EMC VNX5400 Controller failure); DELL EMC VNX5400 电源( PS) 失败(DELL EMC VNX5400 SPS failure); DELL EMC VNX5400 电池( Battery) 失败(DELL EMC VNX5400 Battery failure); DELL EMC VNX5400 备份盘( Spare Disk) 失败(DELL EMC VNX5400 Spare HDD failure); DELL EMC VNX5400 磁盘( HDD) 失败(DELL EMC VNX5400 HDD failure); DELL EMC VNX5400 PCI-Express 交换卡( ESW) 失败(DELL EMC VNX5400 ESW failure); DELL EMC VNX5400 内存条( CM) 失败(DELL EMC VNX5400 CM failure); DELL EMC VNX5400 数据缓存卡( CPC) 失败(DELL EMC VNX5400 CPC failure); DELL EMC VNX5400 后端卡 (DKA) 失败(DELL EMC VNX5400 DKA failure); DELL EMC VNX5400 前端卡 (CHA) 失败(DELL EMC VNX5400 CHA failure); DELL EMC VNX5400 磁盘 失败(DELL EMC VNX5400 Disk failure); DELL EMC VNX5400 电池 失败(DELL EMC VNX5400 Battery failure); DELL EMC VNX5400 控制器间PCIe链路已降级; DELL EMC VNX5400 光纤通道端口不能正常工作; DELL EMC VNX5400 驱动器SAS错误计数超出阈值; DELL EMC VNX5400 光纤通道I/O端口未正常工作; DELL EMC VNX5400 FC 脱机 状态 (DELL EMC VNX5400 FC Offline status); DELL EMC VNX5400 mdisk4 脱机(mdisk4 offline状态); DELL EMC VNX5400 mdisk4 offline; DELL EMC VNX5400 存储池脱机; DELL EMC VNX5400 全盘亮黄灯; DELL EMC VNX5400 更换电池方法; DELL EMC VNX5400 跟换扩展柜方法; DELL EMC VNX5400 跟换交换机方法; DELL EMC VNX5400 更换硬盘方法;

DELL EMC VNX5400 -->解决方法

dell EMC VNXe SP stuck in Service Mode -->解决方法

dell EMC VNXe SPA stuck in Service Mode -->解决方法

dell EMC VNXe SPB stuck in Service Mode -->解决方法

dell EMC VNX5400 SP stuck in Service Mode -->解决方法

dell EMC VNX5400 SPA stuck in Service Mode -->解决方法

dell EMC VNX5400 SPB stuck in Service Mode -->解决方法

dell EMC VNX5400 mode service -->解决方法

中国·北京 联系方式:
1)联系人:   霍经理
2)手 机: 13301272832 (微信同号)
3)QQ: 619804118
4)联系电话:(010)82666745
5)传   真:(010)82666745
6)E-mail:   bjslkc@163.com
7)公司:北京深蓝融鑫科技发展有限公司
8)地址:北京市海淀区西北旺
9)公司地址、乘车路线及公司位置地图
 

Beijing ShenLan Rongxin Technology Development Co., Ltd. All Rights Reserved.
北京深蓝融鑫科技发展有限公司 版权所有,不得转载.
京ICP备05042544号