Storage Processor A (Primary) red light
Storage Processor B red light
存储控制 A (主要) 模式: 服务
存储控制 B 模式: 服务
Storage Processor A (Primary) Mode: Service
Storage Processor B Mode: Service
SPA Empty
SPB Empty
SPA Empty Current State: Not Present
SPB Empty Current State: Not Present
SPA Base Module A Faulted
SPB Base Module B Faulted
SPA CPU Module A Faulted
SPB CPU Module B Faulted
SPA DIMMS A Faulted
SPB DIMMS B Faulted
SPA I/O Modules Empty
SPB I/O Modules Empty
SPA I/O Modules Solt A0 Faulted
SPA I/O Modules Solt A1 Faulted
SPA I/O Modules Solt A2 Faulted
SPA I/O Modules Solt A3 Faulted
SPA I/O Modules Solt A4 Faulted
SPB I/O Modules Solt B0 Faulted
SPB I/O Modules Solt B1 Faulted
SPB I/O Modules Solt B2 Faulted
SPB I/O Modules Solt B3 Faulted
SPB I/O Modules Solt B4 Faulted
SPA Peer Boot State Invalid
SPB Peer Boot State Invalid
SPA Storage System Failure - Contact your Service Representative
SPB Storage System Failure - Contact your Service Representative
Bus 0 Enclosure 0 Disk8 Removed
Bus 0 Enclosure 0 Disk9 Removed
Bus 0 Enclosure 0 Disk10 Removed
Bus 0 Enclosure 0 Disk11 Removed
DPE(Bus 0 Enclosure 0) is faulted
SPS(Bus 0 Enclosure 0 BBU A) is faulted
Bus0 Enclosure 0 Power A Faulted
Bus0 Enclosure 0 Power B Faulted
BMC Indicated I/O Module Powr Disabled Error
EMC Control Station 无法启动
EMC Control Station 无法开机
IE 浏览器 无法访问EMC VNX5600 Unisphere 界面--》报java jre加载问题
Firefox 浏览器 无法访问EMC VNX5600 Unisphere 界面--》报java jre加载问题
Chrome 浏览器 无法访问EMC VNX5600 Unisphere 界面--》报java jre加载问题
IE JRE is required for this application to run.Please refer to the EMC,32-bit
Firefox JRE is required for this application to run.Please refer to the EMC,32-bit
Chrome JRE is required for this application to run.Please refer to the EMC,32-bit
IE JRE is required for this application to run.Please refer to the EMC,64-bit
Firefox JRE is required for this application to run.Please refer to the EMC,64-bit
Chrome JRE is required for this application to run.Please refer to the EMC,64-bit
Chrome JRE is required for this application to run.Please refer to the EMC,64-bit
Error: Unable to establish IPMI v2 / RMCP+ session,ipmitool.exe
how to replace a BBU in a VNX5600 System
how to replace a DPE in a VNX5600 System
how to replace a Disk in a VNX5600 System
how to replace a I/O Module in a VNX5600 System
how to replace a Power in a VNX5600 System
how to replace a Storage Processor (SP) in a VNX5600 System
how to replace a Storage Processor (SP) A in a VNX5600 System
how to replace a Storage Processor (SP) B in a VNX5600 System
怎样更换 BBU in a VNX5600 System
怎样更换 DPE in a VNX5600 System
怎样更换 磁盘 in a VNX5600 System
怎样更换 I/O Module in a VNX5600 System
怎样更换 电源 in a VNX5600 System
怎样更换 Storage Processor (SP) in a VNX5600 System
怎样更换 Storage Processor (SP) A in a VNX5600 System
怎样更换 Storage Processor (SP) B in a VNX5600 System
联系电话/Tel:
Moble: 13301272832 (微信同号)
Tel:  010-82666745
联系人:   霍经理
QQ:   619804118
E-mail:   bjslkc@163.com
公司:北京深蓝融鑫科技发展有限公司

存储控制 A (主要) -->解决方法 状态: 未检测到故障 -->解决方法 模式: 服务 -->解决方法

存储控制 B -->解决方法 状态: 未检测到故障 -->解决方法 模式: 服务 -->解决方法

Storage Processor A (Primary) -->解决方法 Status: There is a problen with the system sofware on this Storage Processor (ADMIN)-->解决方法 Mode: Service -->解决方法 Recommend To attempt to correct this problem,first run Data Collectioon,and then try the follwing in order. Action: Check all cables,reboot each SP,and reimage each Storage Processor(SP) if this does not resolve the lssue,contact you service provider.

Storage Processor B -->解决方法 Status: There is a problen with the system sofware on this Storage Processor (ADMIN)-->解决方法 Mode: Service -->解决方法 Recommend To attempt to correct this problem,first run Data Collectioon,and then try the follwing in order. Action: Check all cables,reboot each SP,and reimage each Storage Processor(SP) if this does not resolve the lssue,contact you service provider.

SPA Empty -->解决方法 SPB Empty -->解决方法 SPA Empty Current State: Not Present,EMC VNX5600 System -->解决方法 SPB Empty Current State: Not Present,EMC VNX5600 System -->解决方法 SPA: Base Module A Faulted -->解决方法 CPU Module A Faulted -->解决方法 DIMMS A Faulted -->解决方法 I/O Modules Empty -->解决方法 Solt A0 Faulted -->解决方法 Solt A2 Faulted Solt A3 Faulted Solt A4 Faulted

SPA Empty: -->解决方法 SP signature: 0x03 Current State: Not Present -->解决方法 Model: VNX5600 Total Memory N/A Committed Memory N/A Firmware Revison: N/A PROM Revision: N/A Illegal Cross Loop: N/A Enclosure Cabing Order: N/A SCSI Target ID: N/A Serial Number: Peer Boot State Invalid -->解决方法

SPB Empty: -->解决方法 SP signature: 0x03 Current State: Not Present -->解决方法 Model: VNX5600 Total Memory N/A Committed Memory N/A Firmware Revison: N/A PROM Revision: N/A Illegal Cross Loop: N/A Enclosure Cabing Order: N/A SCSI Target ID: N/A Serial Number: Peer Boot State Invalid -->解决方法

**************************************************************** Extended POST Messages **************************************************************** ....Storage System Failure - Contact your Service Representative ...

**************************************************************** Extended POST Messages **************************************************************** ....Storage System Failure - Contact your Service Representative ... WARNING: Couldn't read sensor (0x2c) WARNING: Couldn't read sensor (0x2c) WARNING: Couldn't read Chassis status WARNING: Couldn't read sensor (0x38) WARNING: Couldn't read Chassis status WARNING: Couldn't read sensor (0x2c) WARNING: Couldn't read Chassis status WARNING: Couldn't read sensor (0x38)

**************************************************************** Extended POST Messages **************************************************************** ....Storage System Failure - Contact your Service Representative ... ErrorCode: 0X00000907 ErrorDesc: FRU: I/O Module 0 Device: I/O Card 0 Description: BMC indicated I/O module powr disabled Error! Rev: 61.00 Determine Module* P/N: 303-161-103B-04 S/N: EndError: ErrorTime: WARNING: Couldn't read sensor (0x2c) WARNING: Couldn't read sensor (0x2c) WARNING: Couldn't read Chassis status WARNING: Couldn't read sensor (0x38) WARNING: Couldn't read Chassis status WARNING: Couldn't read sensor (0x2c) WARNING: Couldn't read Chassis status WARNING: Couldn't read sensor (0x38)

I/O Module Faulted -->解决方法 BBU Faulted -->解决方法 DISK Removed -->解决方法

I/O Module Faulted -->解决方法 Solt A0 Faulted Cannot turn flashing on/off for all the ports in the Slot A0 because the SP IS down. Solt A1 Faulted Cannot turn flashing on/off for all the ports in the Slot A0 because the SP IS down. Solt A2 Faulted Cannot turn flashing on/off for all the ports in the Slot A0 because the SP IS down. Solt A3 Faulted Cannot turn flashing on/off for all the ports in the Slot A0 because the SP IS down.

I/O Module Faulted -->解决方法 Solt B0 Faulted Cannot turn flashing on/off for all the ports in the Slot A0 because the SP IS down. Solt B1 Faulted Cannot turn flashing on/off for all the ports in the Slot A0 because the SP IS down. Solt B2 Faulted Cannot turn flashing on/off for all the ports in the Slot A0 because the SP IS down. Solt B3 Faulted Cannot turn flashing on/off for all the ports in the Slot A0 because the SP IS down.

Bus 0 Enclosure 0 Disk1 Removed Bus 0 Enclosure 0 Disk2 Removed Bus 0 Enclosure 0 Disk3 Removed Bus 0 Enclosure 0 Disk4 Removed Bus 0 Enclosure 0 Disk5 Removed Bus 0 Enclosure 0 Disk6 Removed Bus 0 Enclosure 0 Disk7 Removed Bus 0 Enclosure 0 Disk8 Removed Bus 0 Enclosure 0 Disk9 Removed Bus 0 Enclosure 0 Disk10 Removed Bus 0 Enclosure 0 Disk11 Removed Bus 0 Enclosure 0 Disk12 Removed Bus 0 Enclosure 0 Disk13 Removed Bus 0 Enclosure 0 Disk14 Removed Bus 0 Enclosure 0 Disk15 Removed Bus 0 Enclosure 0 Disk16 Removed Bus 0 Enclosure 0 Disk17 Removed Bus 0 Enclosure 0 Disk18 Removed Bus 0 Enclosure 0 Disk19 Removed Bus 0 Enclosure 0 Disk20 Removed Bus 0 Enclosure 0 Disk21 Removed Bus 0 Enclosure 0 Disk22 Removed Bus 0 Enclosure 0 Disk23 Removed Bus 0 Enclosure 0 Disk24 Removed

Alert Details: TF-EMC-5600 Severity: Error System: TF-EMC-5600 Domain: Local Created: Message: DPE(Bus 0 Enclosure 0) is faulted Full Description: Disk Process Enclosure (Bus 0 Enclosure 0) is faulted. Servers may have lost access to disk drives in this storage system Recommended Action:Contact your service provider Event Code:0x7409

Alert Details: TF-EMC-5600 Severity: Error System: TF-EMC-5600 Domain: Local Created: Message: Unisphere can no longer manage(SPA) Full Description: Unisphere can no longer manager the other storage processor(SPA) in this storage system.Server I/O to the storage system is not impacted by this. Recommended Action: Verify that the storage processor has a valid management Lan connection and that the SP does not have a hardware fault. Event Code:0x743a

Alert Details: TF-EMC-5600 Severity: Error System: TF-EMC-5600 Domain: Local Created: Message: SPS(Bus 0 Enclosure 0 BBU A) is faulted Full Description: Standby Power Supply (Bus 0 Enclosure 0 BBU A) is faulted. Recommended Action: Verity that power cables and the communications (serial) cable are connected property between the storage system and the sps. if the SPS has completed charging its.battery and the problem still persists contact your service provider Event Code:0x7404

Power Supplies Bus0 Enclosure 0 Power A Faulted -->解决方法 Bus0 Enclosure 0 Power B Faulted -->解决方法

EMC Control Station 无法启动 -->解决方法 EMC Control Station 无法开机 -->解决方法 Booting 'EMC Celerra Control Station Linux' root (hd0,0) Filesystem type is ext2fs,partition type 0x03 kernel /vmlinuz ro root=/dev/hda3 console=ttyS1,19200 [Linux-bzImage, setup=0x1e00,size=0x1d1b14] initrd /initrd.img[Linux-initrd @ 0x37dcf000,0x220117 bytes] -->解决方法

IE浏览器 无法访问EMC VNX5600 Unisphere 界面--》报java jre加载问题 IE浏览器 无法访问EMC VNX5600 Unisphere 界面--》报java jre加载问题 google浏览器 需要JRE 运行支持包

JRE is required for this application to run.Please refer to the EMC product release notes for supported JRE version Please visit http://www.oracle.com to install the 32-bit version for JRE

JRE is required for this application to run.Please refer to the EMC product release notes for supported JRE version Please visit http://www.oracle.com to install the 64-bit version for JRE

JRE error

DELL EMC VNX5100 -->解决方法

dell EMC VNXe SP stuck in Service Mode -->解决方法

dell EMC VNXe SPA stuck in Service Mode -->解决方法

dell EMC VNXe SPB stuck in Service Mode -->解决方法

dell EMC VNX5100 SP stuck in Service Mode -->解决方法

dell EMC VNX5100 SPA stuck in Service Mode -->解决方法

dell EMC VNX5100 SPB stuck in Service Mode -->解决方法

dell EMC VNX5100 mode service -->解决方法

how to replace a Storage Processor (SP) in a VNX5600 System. -->解决方法 how to replace a Storage Processor (SPA) in a VNX5600 System.-->解决方法 how to replace a Storage Processor (SPB) in a VNX5600 System.-->解决方法 How to replace a Disk in a VNX5600 System -->解决方法 How to replace a Power in a VNX5600 System -->解决方法 How to replace a I/O Module in a VNX5600 System How to replace a BBU in a VNX5600 System How to replace a DPE in a VNX5600 System

How to get to CLI in Unisphere -->解决方法 How to enter Command Line Interface (CLI) via the Unisphere Manager GUI. (User Correctable) Dell EMC Unity: How to Enable or disable Secure Shell on the system. (User Correctable) How to gather SP Collects using CLI only (User Correctable)

how to replace a Storage Processor (SP) in a EMC VNXe or VNX System. -->解决方法 how to replace a Storage Processor (SPA) in a EMC VNXe or VNX System. how to replace a Storage Processor (SPB) in a EMC VNXe or VNX System. How to replace a Disk in a EMC VNXe or VNX System -->解决方法 How to replace a Power in a EMC VNXe or VNX System -->解决方法 How to replace a I/O Module in a EMC VNXe or VNX System How to replace a BBU in a EMC VNXe or VNX System How to replace a DPE in a EMC VNXe or VNX System

how to replace a Storage Processor (SP) in a VNXe System. -->解决方法 how to replace a Storage Processor (SPA) in a VNXe System. how to replace a Storage Processor (SPB) in a VNXe System. How to replace a Disk in a VNXe System -->解决方法 How to replace a Power in a VNXe System -->解决方法 How to replace a I/O Module in a VNXe System How to replace a BBU in a VNXe System How to replace a DPE in a VNXe System

how to replace a Storage Processor (SP) in a VNX System. -->解决方法 how to replace a Storage Processor (SPA) in a VNX System. how to replace a Storage Processor (SPB) in a VNX System. How to replace a Disk in a VNX System -->解决方法 How to replace a Power in a VNX System -->解决方法 How to replace a I/O Module in a VNX System How to replace a BBU in a VNX System How to replace a DPE in a VNX System

如何更换VNX5100系统中的存储处理器(SP) -->解决方法 如何更换VNX5100系统中的存储处理器(SPA)-->解决方法 如何更换VNX5100系统中的存储处理器(SPB)-->解决方法 如何更换VNX5200系统中的磁盘-->解决方法 如何更换VNX5200系统中的电源-->解决方法 如何更换VNX5200系统中的I/O模块 如何在VNX5600系统中更换BBU 如何在VNX5600系统中更换DPE

如何在Unisphere中访问CLI-->解决方法 如何通过Unisphere Manager GUI进入命令行界面(CLI)(用户可更正) Dell EMC Unity:如何在系统上启用或禁用Secure Shell(用户可更正) 如何仅使用CLI收集SP收集(用户可更正)

如何更换EMC VNXe或VNX系统中的存储处理器(SP) -->解决方法 如何更换EMC VNXe或VNX系统中的存储处理器(SPA)-->解决方法 如何更换EMC VNXe或VNX系统中的存储处理器(SPB)-->解决方法 如何更换EMC VNXe或VNX系统中的磁盘-->解决方法 如何更换EMC VNXe或VNX系统中的电源-->解决方法 如何更换EMC VNXe或VNX系统中的I/O模块 如何更换EMC VNXe或VNX系统中的BBU 如何在EMC VNXe或VNX系统中更换DPE

如何更换EMC VNXe 系统中的存储处理器(SP) -->解决方法 如何更换EMC VNXe 系统中的存储处理器(SPA)-->解决方法 如何更换EMC VNXe 系统中的存储处理器(SPB)-->解决方法 如何更换EMC VNXe 系统中的磁盘-->解决方法 如何更换EMC VNXe 系统中的电源-->解决方法 如何更换EMC VNXe 系统中的I/O模块 如何更换EMC VNXe 系统中的BBU 如何在EMC VNXe 系统中更换DPE

如何更换EMC VNX 系统中的存储处理器(SP) -->解决方法 如何更换EMC VNX 系统中的存储处理器(SPA)-->解决方法 如何更换EMC VNX 系统中的存储处理器(SPB)-->解决方法 如何更换EMC VNX 系统中的磁盘-->解决方法 如何更换EMC VNX 系统中的电源-->解决方法 如何更换EMC VNX 系统中的I/O模块 如何更换EMC VNX 系统中的BBU 如何在EMC VNX 系统中更换DPE

中国·北京 联系方式:
1)联系人:   霍经理
2)手 机: 13301272832 (微信同号)
3)QQ: 619804118
4)联系电话:(010)82666745
5)传   真:(010)82666745
6)E-mail:   bjslkc@163.com
7)公司:北京深蓝融鑫科技发展有限公司
8)地址:北京市海淀区西北旺
9)公司地址、乘车路线及公司位置地图
 

Beijing ShenLan Rongxin Technology Development Co., Ltd. All Rights Reserved.
北京深蓝融鑫科技发展有限公司 版权所有,不得转载.
京ICP备05042544号